EasyCoat is a two-component, 100% solids polyamide epoxy coating, with no solvents or volatile organic compounds (VOC 0 g/L). It is applied by brush, roller or airless spray, up to 250 µm dry film thickness per coat. It can be used as a single coat or combined with other coatings, on prepared steel or on well-adhered aged coatings.

Where it is used

  • Exterior of pipelines and piping, buried or above ground.
  • Coating repair and weld joints on site.
  • Tanks.
  • Metal structures exposed to aggressive atmospheres.

Technical data

TypePolyamide epoxy, two components
Volume solids100%
VOC0 g/L
Mix ratio1:1 by volume (A:B)
Density1.41 ± 0.02 kg/L
Dry film thicknessUp to 250 µm per coat; up to 750 µm in 3 coats
Coverage3.8 m²/L at 250 µm
Pot life60 min at 25 °C
Drying at 25 °CTouch dry, 4 h – hard dry, 15 h
Recoat interval8 to 24 h; maximum 72 h, sanding if exceeded
Full cure7 days
Service temperature−30 to +90 °C continuous
Storage12 months, at 10 °C or above

How to apply it

  1. Remove the existing coating and degrease the surface with EasyWipe-E®. Then clean by abrasive blasting (Sa 2 / SSPC-SP 6 on above-ground pipes and Sa 2½ / SSPC-SP 10 on buried pipes) or by power tool cleaning to bare metal (SSPC-SP 11).

  2. The surface must be at least 3 °C above the dew point. Apply EasyCoat within 4 h after cleaning.

  3. Pour part B into part A and mix for 5 min. Use the mix within 60 min (at 25 °C) and do not thin it.

  4. Apply by brush, roller or airless spray, up to 250 µm dry film thickness per coat. For higher thickness, apply successive coats every 8 to 24 h.

  5. Check wet film thickness on each pass, dry film thickness at the end, and continuity over the whole surface with a holiday detector.

Before backfilling or immersion, observe the times in the data sheet. On request, we provide the surface preparation and application instructions, including the one for welded joints. Would you rather we apply it? See Recoating.

Two workers applying EasyCoat® to an exposed pipeline in an excavation.

Packaging

  • 4 L kit: 2 L of part A and 2 L of part B.
  • 8 and 20 L kits, on request.
  • Color: dark gray.

Accessories

  • EasyCoat Preparation Kit: mixing buckets, stirring sticks, gloves and application tools. Assembled to order.

  • EasyWipe-E®: solvent for degreasing and cleaning the surface before applying EasyCoat.

Calculate how much EasyCoat you need

Enter the surface and the thickness. You get the liters, the weight and the kits to request a quote.

Calculation without the calculator: liters = surface (m²) × dry film thickness (µm) ÷ 950 ÷ (1 − losses). Reference losses: 15% with brush or roller and 30% with airless. Example: 100 m² at 250 µm with 15% losses gives 31 L, that is, 8 kits of 4 L.

What you are coating
100 m Ø 323.9 mm
Pipe outside diameter.
µm
250 µm – 1 coat750 µm – 3 coats

Application recommendation: do not exceed 250 µm dry film per coat. For higher thicknesses, apply successive coats.

Suggested distribution: 1 coat

How you will apply it
Starting value. Adjust it based on your site experience.
You need
31.5L
With 15% application losses, at 250 µm total dry film thickness.
Surface to coat
101.8 m²
Coverage at 250 µm
3.80 m²/L
Consumption without losses
26.8 L
Product weight
44.4 kg
4 L kits (2 L A + 2 L B)
8 × 4 L
Total 32 L: 16 L of part A and 16 L of part B. 0.5 L left over. 8 and 20 L kits on request.
Request a quote with this calculation

Takes you to Contact with EasyCoat and the calculation already loaded. If you prefer, send it by WhatsApp or .

Send the request by WhatsApp

Mix a little at a time

The mix lasts 60 minutes at 25 °C. Prepare only what you will apply in that time.

Estimate based on the coverage in the EasyCoat® data sheet: 3.8 m²/L at 250 µm dry film. Actual consumption may vary with the anchor profile, geometry, applied thickness and application method.

Downloads

Technical data sheet (PDF, in Spanish)

Safety data sheets: on request.

Need EasyCoat?

Request a quote with the number of kits or send us the calculator result.